LOGIQ-P8-Product-Data-Sheet
Preview — first 14 pages
[Page 1] GE Healthcare LOGIQ P8 MAKE IT EASY. MAKE IT YOUR OWN Product description The LOGIQ P8 is a workhorse for the demanding physician. Its flagship imaging engine is the foundation for finding the root of the patient’s problem, even in difficult patients. Buttons on the transducer turn three-handed procedures into two-handed procedures, giving the physician more control. It all adds up to a system that’s walk -up easy-to-use on day one and for the most challenging procedures.
[Page 2] Urological General Specification Pediatric & Neonatal Intraoperative Dimensions and Weight Cardiac Height Articulating monitor arm Transcranial 1,345mm~1,595mm (53.0 in ~ 62.8 in) Endocavitary (transvaginal, transrectal) Keyboard: 430 mm (16.9 in) Transesophageal Width Foot cover: 495 mm (19.5 in) Monitor: 545mm [23.8inch Scanning Methods Bezel-less LCD] Electronic sector Depth Foot cover: 685 mm (27.0 in) Electronic convex Rear handle: 740 mm (29.1 in) Electronic micro convex Weight (max. load) 83 kg/183 lbs Electronic linear Weight (min. load) 67 kg/148 lbs Real-time 4D volume sweep Electrical Power Transducer Types Voltage 100 – 240 Vac Sector phased array Frequency 50/60 Hz Convex array Power consumption maximum of 500 VA with Microconvex array peripherals Linear array Matrix array Console Design Single CW (pencil) probes 4 active probe ports (3 x RS and 1 x DLP) Volume probes (4D) Integrated Solid State Drive Integrated DVD multi-drive (option) Operating Modes On board storage for BW printer B-Mode Integrated speakers Coded Harmonic Imaging Probe holders M-Mode Front handle Color Flow Mode (CFM) Gel warmer (option) Power Doppler Imaging (PDI) Rear handle (option) PW Doppler with high PRF Probe light M-Color Flow Mode Anatomical M-Mode Curved Anatomical M-Mode User Interface B- Flow™/B -Flow Color (option) Operator Keyboard Extended Field of View (LOGIQView option) Ergonomic full size keyboard Coded Contrast Imaging (option) Swivel-adjustable, height-adjustable CW Doppler Mode (option) Digital TGC and digital A/N keyboard TVI Mode (option) Physical A/N keyboard (option) Strain Elastography (option) 10.4'' LCD touch screen Shear Wave Elastography (option) 3D/4D Volume Modes (option) HD live (option) Monitor Offline Scanning Mode (option) 23.8inch Bezel-less LCD LED backlight monitor B-Steer + (option) System Overview System Standard Features Advanced User Interface with High Resolution Applications 10.4'' Wide LCD Touch Screen Abdominal Automatic Optimization Obstetrical CrossXBeam Compounding Gynecological Speckle Reduction Imaging (SRI-HD) Breast Fine Angle Steering Small parts Coded Harmonic Imaging Musculoskeletal Vascular Virtual Convex
[Page 3] Patient Information Database SonoAVC Image Archive on Integrated CD/DVD (option) and SonoNT/SonoIT SSD Start Assistant Raw Data Analysis Real-Time Automatic Doppler Calculations Peripheral Options OB Calculations Integrated Options for • Digital BW thermal Fetal Trending printer Email to MMS • HDMI output available MyTrainer+ for compatible devices Privacy and Security • S -Video output Qpath available for compatible Tricefy devices Multigestational Touch Control • Wireless LAN card for InSite™ Capability wireless data transfer IOTA (International Ovarian Tumor Analysis) LR2 • External USB printer worksheet connection Vnav Import • Power Assistant Doppler Assistant (battery or extended MyPreset battery Option) for SonoRenderLive offl ine scanning Digital color thermal printer Foot switch with programmable functionality System Options Universal video converter Auto IMT 4 Barcode reader Advanced 3D LOGIQ P Apps (Bluetooth) Cable hook rear 4 Ethernet protection cable Card reader mounting kit Strain Elastography Elastography Quantification Display Modes DICOM (DICOM® 3.0 Connectivity) Live and stored display format: full size and split LOGIQView screen – both with “thumbnails” for still and Cine B-Flow/B-Flow Color Review image format: 4x4 and “thumbnails” for still CF/PDI Quantification (FlowQA) and Cine Breast Productivity Package Simultaneous capability Thyroid Productivity Package B or CrossXBeam/PW Measure Assist OB B or CrossXBeam/CFM or PDI AutoEF B/M B Steer+ B/CrossXBeam Stress Echo Real-time Triplex Mode (B or CrossXBeam + CFM or Tissue Velocity Imaging (TVI) with Q-Analysis PDI/PW or CW (Option) Scan Assistant Selectable Alternating Modes Compare Assistant B or CrossXBeam/PW Report Writer B or CrossXBeam + CFM (PDI)/PW(CW (option)) Cardiac Strain B/CW (Option) STIC Multi-image (split/quad screen) OmniView Live and/or frozen Shear Wave Elastography B or CrossXBeam + B or CrossXBeam/CFM or PDI LOGIQ P Apps Independent Cine playback HDlive™ Timeline display Coded Contrast (CEUS) Independent dual B or CrossXBeam/PW display HRES CEUS CW Koios Breast Lesion Decision Support Display formats • Top/bottom selectable Koios Thyroid Lesion Decision Support format Hepatic Assistant • Side/side selectable Digital Expert format UGAP Virtual convex Software DVR Basic Timeline only Software DVR
[Page 4] Color scale: 3 types • Power Display Annotation • Directional PDI Patient Name: first, last and middle • Symmetrical velocity Patient ID imaging Alternate patient ID Color velocity range and baseline Age, sex and birth date Color threshold marker Hospital name Color gain Date format: • MM/DD/YY PDI 3 types selectable • DD/MM/YY Inversion • YY/MM/DD Doppler frequency Time format: • 24 hours TGC curve 2 types selectable • 12 hours Cine gage, image number/frame number Gestational age from • LMP Body pattern: multiple human and animal types • GA Application name • EDD Measurement results • BBT Displayed acoustic • TIS: Thermal Index Operator message output Soft Tissue Biopsy guide line and zone • TIC: Thermal Index Heart rate Cranial (Bone) • TIB: Thermal Index Bone • MI: Mechanical Index General System Parameters % of maximum power output System Setup Probe name Pre-programmable categories Map names User programmable preset capability Probe orientation Factory default preset data Depth scale marker Languages: English, French, German, Spanish, Lateral scale marker Italian, Portuguese, Russian, Greek, Swedish, Focal zone markers Danish, Dutch, Finnish, Norwegian, Japanese Image depth (message only), Chinese (message only) Zoom depth OB report formats including Tokyo Univ., Osaka B-Mode Univ., USA, Europe, and ASUM Gain User defined annotations Dynamic range Body patterns Imaging frequency Customized comment home position Frame averaging Reset Acoustic frame rate Gray map Complete User Manual Available On-Board SRI-HD Through Help (F1) M-Mode User manual and service manual are included on Gain USB with each system. A printed manual is Dynamic range available upon request. Time scale Doppler mode Gain CINE Memory/Image Memory Angle 776 MB of Cine memory Sample volume depth and width Selectable cine sequence for Cine review Wall filter Prospective Cine mark Velocity and/or frequency scale Measurements/calculations and annotations on Spectrum inversion Cine playback Time scale Scrolling timeline memory PRF Dual image Cine display Doppler frequency Quad image Cine display Color Flow Mode Cine gauge and Cine image number display Line density Cine review loop Frame averaging Cine review speed Packet size Image Storage
[Page 5] On-board database of patient information from Formats various exam results into a report suitable past exams for Storage formats: • DICOM – compressed/ printing or reviewing on a standard PC uncompressed, single/ Exam result reports can include patient info, exam multiframe, with/without info, measurements, calculations, images, raw data comments and physician diagnosis • Export JPEG, JPEG2000, Standard templates provided WMV, MPEG 4 and AVI Customizable templates formats Thyroid reporting template Storage devices: • USB memory Stick: 64 MB Scanning Parameters to 4 GB (for exporting Displayed imaging depth: 0 – 48 cm individual images/clips) • CD -R storage: 700 MB Minimum depth of field: 0 – 1 cm (zoom) (probe • DVD storage: -R (4.7 dependent) GB) Maximum depth of field: 0 – 48 cm (probe • Solid state drive image dependent) storage:~345GB Continuous dynamic receive focus/continuous Compare old images with current exam dynamic Reload of archived data sets Receive aperture Adjustable dynamic range Adjustable Field of View (FOV) Connectivity & DICOM Image reverse: right/left Ethernet network connection Image rotation of 0°, 90°, 180°, 270° DICOM 3.0 (Option) Wireless LAN (Option) Verify Digital B-Mode Print Adjustable: • Acoustic power Store • Gain Modality worklist • Dynamic range • Frame averaging Storage commitment • Gray scale map Modality Performed Procedure Step (MPPS) • Frequency Media exchange • Line density Off network/mobile storage queue • Scanning size (FOV or Query/retrieve angle – Public SR template • Structured reporting – depending on the probe, compatible with vascular see probe specifications) and OB standard • B colorization • Direct export DICOM SR • Reject and XML • Suppression Remote capability InSite ™ ExC • SRI -HD DICOM directory import • Edge enhance LOGIQ P Apps (Option) Digital M-Mode Physiological Input Panel (Option) Adjustable: • Acoustic power Physiological input • Gain ECG, 2 lead • Dynamic range Dual R-Trigger • Gray scale map Pre-settable ECG R delay time • Frequency Pre-settable ECG position • Sweep speed Adjustable ECG gain control • M colorization Automatic heart rate display • M display format • Rejection Report Writer (Option) On-board reporting package automates report Anatomical M-Mode writing M-Mode cursor adjustable at any plane Can be activated from a Cine loop from a live or stored image
[Page 6] M and A capability • Accumulation mode Available with Color Flow Mode • Sample volume control Curved Anatomical M-Mode • Flash suppression Digital Spectral Doppler Mode Continuous Wave Doppler (Option) Adjustable: • Acoustic power Adjustable: • Acoustic power • Gain • Gain • Dynamic range • Dynamic range • Gray scale map • Gray scale map • Transmit frequency • Transmit frequency • Wall filter • Wall filter • PW colorization • CW colorization • Velocity scale range • Velocity scale range • Sweep speed • Sweep speed • Sample volume length • Angle correction • Angle correction • Spectrum inversion • Steered linear • Trace method • Spectrum inversion • Baseline shift • Trace method • Doppler auto trace • Baseline shift • Compression • Doppler auto trace • Trace direction • Time resolution • Trace sensitivity • Compression Available on 3Sc-RS, 6S-RS, 12S-RS, 6Tc-RS, P2D, • Trace direction P6D and P8D probes • Trace sensitivity Automatic Optimization Digital Color Flow Mode Optimize B-Mode image to improve contrast Adjustable: • Acoustic power resolution • Color maps, including Selectable amount of contrast resolution velocity-variance maps improvement (low, medium, high) • Gain Auto TGC • Velocity scale range Auto-spectral optimize • Baseline • Wall filter adjusts • Invert • Packet size • PRF (on live image) • Line density • Angle correction • Spatial filter • Steering angle Coded Harmonic Imaging • Baseline shift Available on all 2D probes and 4D probes • Frame average • Threshold • Accumulation mode B-Flow/B-Flow Color (Option) • Sample volume control • Flash suppression • Quantification ( Option) E8CS-RS, IC9-RS, BE9CS-RS, C2-7-D and 10C-D probes Background: on/off Digital Power Doppler Imaging Sensitivity/PRI Adjustable: • Acoustic power • Color maps including Line density velocity-variance maps Edge enhance • Gain Frame average • Velocity scale range Gray scale map • Wall filter Tint map • Packet size Dynamic range • Line density Rejection • Spatial filter Gain • Steering angle Hybrid B-Flow • Supported on C1 -5- • Frame average RS, 12L-RS, 9L-RS, ML6- • Threshold 15-RS, L4-12t-RS, L3-
[Page 7] 12-RS, C2-7-D and 10C- Acquisition of color data D probes Automatic rendering • B & B -Flow 3D landscape technology simultaneous 3D movie dual display • B & B -Flow overlay Real-time 4D (Option) display Acquisition modes B-Flow Color (BFC) • Real-time 4D B-Flow High Definition Supported on C1-5-RS, • Static 3D Color 12L-RS, ML6-15-RS, L4- Visualization modes • 3D rendering (diverse (HD Color) 12t-RS and L3-12-RS surface and intensity probes projection modes) Accumulation • Sectional planes (three section planes perpendicular to each Coded Contrast Imaging (Option) other) Available on C1-5-RS, 3Sc-RS, IC9-RS, BE9CS-RS, • Volume contrast 9L-RS and C2-7-D probes imaging-static (Option) 2 contrast timers • Tomographic Timed updates: 0.05 – 10 seconds ultrasound imaging Accumulation mode, six levels (Option) Maximum Enhance Mode Render mode Surface texture, surface Flash smooth, max-, min- and Time Intensity Curve (TIC) Analysis X-ray (average intensity Auto MI control projection), The LOGIQ P8 is designed for compatibility with mix mode of two render commercially available ultrasound contrast agents. modes Because the availability of these agents is subject Curved 3 point render start to government regulation and approval, product 3D movie features intended for use with these agents Scalpel: 3D cut tool may not be commercially marketed nor made Display format available before the contrast agent is cleared for • Quad: A-/B-/C- use. Contrast related product features are enabled Plane/3D only on systems for delivery to an authorized • Dual: A-Plane/3D country or region of use • Single: 3D or A- or B- or C-Plane LOGIQ View (Option) Automated Volume Calculation – VOCAL II Extended Field of View imaging (Option) Betaview Auto sweep E8C-RS, E8CS-RS, IC9-RS, BE9CS-RS, RIC5-9A, 6Tc- STIC (Option) RS, RAB2-6-RS, 3SC-RS,6S-RS,12S-RS, C2-7-D and HD live ™ (Option) 10C-D probes VCI Static (Option) For use in B-Mode Omniview (Option) VCI OmniView CrossXBeam is available on linear probes Auto detection of scan direction Scan Assistant (Option) Factory programs Pre or post-process zoom User defined programs Rotation Steps include image annotations, mode transitions, Auto fit on monitor basic Measurements in B-Mode imaging controls and measurement initiation 3D Shear Wave Elastography (Option) Allows unlimited rotation and planar translations Available on C1-5-RS, L3-12-RS, IC9-RS, ML6-15-RS 3D reconstruction from Cine sweep and 12L-RS probes User programmable measurement display in kPa and meters per sec Advanced 3D (Option)
[Page 8] Single and dual view display Breast Productivity Package (Option) Worksheet summary includes measurements and B Steer+ (Option) locations for nodule, parathyroid and lymph node Available on C1-5-RS, 8C-RS, L6-12-RS, 12L-RS, 9L- Feature assessment RS, ML6-15-RS, L4-12t-RS, L3-12-RS, RAB2-6-RS, BI-RADS® assessment C2-7-D and 10C-D probes User editable Strain Elastography (Option) Thyroid Productivity Package (Option) Available on C1-5-RS, L6-12-RS, 12L-RS, ML6-15- Worksheet summary includes measurements and RS, L4-12t-RS, L3-12-RS, IC9-RS, E8CS-RS, BE9CS- locations for nodule, parathyroid and lymph node RS and 9L-RS probes Feature assessment Semi-Quantification User editable TVI (Option) Auto EF (Option) Myocardial doppler imaging with color overlay on Allows semi-automatic measurement of the global tissue image EF (Ejection fraction) Available on the sector probes User editable Tissue color overlay can be removed to show just the 2D image, still retaining the tissue velocity Cardiac Strain (Cardiac AFI) (Option) information Allows assessing the left ventricle with all Curved anatomical M-Mode: free (curved) drawing segments at a glance by combining three of M-Mode generated from the cursor independent longitudinal views into one comprehensive bulls- from the axial plane eye view Q-Analysis: multiple time motion trace display 2D strain based data moves into clinical practice from selected points in the myocardium Virtual Convex Stress Echo (Option) Provides a convex Field of View Advanced and flexible Stress Echo examination Compatible with CrossXBeam capabilities Available on all linear and sector transducers Provides exercise and pharmacological protocol templates 8 default templates SRI-HD Template editor for user configuration of existing Speckle Reduction Imaging templates or creation of new templates Provides multiple levels of speckle reduction Reference scan display during acquisition for stress Compatible with side-by-side DualView display level comparison (dual screen) Compatible with all linear, convex and sector Baseline level/previous level selectable transducers Raw data continuous capture Compatible with B-Mode, color, contrast agent and Over 100 sec. available 3D imaging Wall motion scoring (bulls-eye and segmental) Smart stress: automatically set up various CrossXBeam scanning parameters (for instance, geometry, Provides 3, 5, 7 or 9 angles of spatial compounding frequency, gain, etc.) according to same projection Live side-by-side DualView display on previous level Compatible with: • Color Mode • PW Compare Assistant (Option) • SRI -HD Allows side-by-side comparison of previous • Coded harmonic ultrasound and other modality exams during live imaging scanning • Virtual convex Power Assistant (Option) E8C-RS, E8CS-RS, BE9CS-RS, IC9-RS, RIC5-9A-RS, Allows moving the system without a complete RAB2-6-RS, C2-7-D and 10C-D probes system shutdown and boot-up power cycle Extended battery for off line scanning (Option) provides battery powered live scanning Controls Available While “Live” Write zoom
[Page 9] B/M/CrossXBeam Mode Display format Gain Doppler audio TGC Angle correct Dynamic range Quick angle correct Acoustic output Auto angle correct Transmission focus position Color flow Transmission focus number Overall gain (loops and stills) Line density control Color map Sweep speed for M-Mode Transparency map Number of angles for CrossXBeam Frame averaging (loops only) PW-Mode Flash suppression Gain CFM display threshold Dynamic range Spectral invert for Color/Doppler Acoustic output Anatomical M-Mode on Cine loop Transmission frequency PRF Wall filter Measurements/Calculations Spectral averaging General B-Mode Sample volume gate • Length Depth and distance • Depth Circumference (ellipse/trace) Velocity scale Area (ellipse/trace) Color Flow Mode Volume (ellipsoid) CFM gain % Stenosis (area or diameter) CFM velocity range Angle between two lines Acoustic output Wall echo filter General M-Mode Packet size M-Depth Frame rate control Distance CFM spatial filter Time CFM frame averaging Slope CFM line resolution Heart rate Frequency/velocity baseline shift General Doppler Measurements/Calculations Velocity Controls Available on “Freeze” or Recall Automatic optimization Time SRI-HD A/B ratio (velocities/frequency ratio) CrossXBeam – display non-compounded and PS (Peak Systole) compounded ED (End Diastole) image simultaneously in split screen PS/ED (PS/ED ratio) 3D reconstruction from a stored Cine loop ED/PS (ED/PS ratio) B/M/CrossXBeam Mode AT (Acceleration Time) Gray map optimization ACCEL (Acceleration) TGC TAMAX (Time Averaged Maximum Velocity) Colorized B and M Volume Flow (TAMEAN and vessel area) Frame average (loops only) Heart rate Dynamic range: Anatomical M-Mode PI (Pulsatility Index) Max Read Zoom to 20x: baseline shift RI (Resistivity Index) Sweep speed PW Mode Real-time Doppler Auto Gray map Measurements/Calculations Post gain PS (Peak Systole) Baseline shift ED (End Diastole) Sweep speed MD (Minimum Diastole) Invert spectral wave form PI (Pulsatility Index) Compression RI (Resistivity Index) Rejection AT (Acceleration Time) Colorized spectrum ACC (Acceleration)
[Page 10] PS/ED (PS/ED ratio) OB Measurements/Calculations ED/PS (ED/PS ratio) Systolic Velocity) HR (Heart Rate) • MCA CP(Middle TAMAX (Time Averaged Maximum Velocity) Cerebral Artery PVAL (Peak Velocity Value) Pulsatility Index Over Volume Flow (TAMEAN and vessel area) Umbilical Artery Pulsatility Index Ratio) • MCA PI(Middle Cerebral OB Measurements/Calculations PI) Gestational age by: • GS (Gestational Sac) • MCA RI(Middle Cerebral • CRL (Crown Rump RI) Length) • UmbArt PI(Umbilical • FL (Femur Length) artery PI) • BPD (Biparietal • UmbArt RI(Umbilical Diameter) artery RI) • AC (Abdominal • UtArt PI(Uterine artery Circumference) PI) • HC (Head • UtArt RI(Uterine artery Circumference) RI) • APTD x TTD (Anterior/ Measurements/calculations by: ASUM, ASUM 2001, Posterior Trunk Diameter Berkowitz, Bertagnoli, Brenner, Campbell, CFEF, by Chitty, Eik-Nes, Ericksen, Goldstein, Hadlock, Transverse Trunk Hansmann, Hellman, Hill, Hohler, Jeanty, JSUM, Diameter) Kurtz, Mayden, Mercer, Merz, Moore, Nelson, Osaka • FTA (Fetal Trunk University, Paris, Rempen, Robinson, Shepard, cross-sectional Area) Shepard/Warsoff, Tokyo University, • BD (Binocular Distance) Tokyo/Shinozuka, Yarkoni • HL (Humerus Length) Fetal graphical trending • FT (Foot Length) • OFD (Occipital Frontal Growth percentiles Diameter) Multi-gestational calculations (4) • TAD (Transverse Fetal qualitative description (anatomical survey) Abdominal Fetal environmental description (biophysical Diameter) profile) • TCD (Transverse Programmable OB tables Cerebellum Over 20 selectable OB calculations Diameter) Expanded worksheets • THD (Thorax Transverse Diameter) GYN Measurements/Calculations • TIB (Tibia Length) Right ovary length, width, height • ULNA (Ulna Length) Left ovary length, width, height Estimated fetal weight • AC, BPD Uterus length, width, height (EFW) by: • AC, BPD, FL Cervix length, trace • AC, BPD, FL, HC Ovarian volume • AC, FL ENDO (Endometrial Thickness) • AC, FL, HC Ovarian RI • AC, HC Uterine RI • BPD, APTD, TTD, FL Follicular measurements • BPD, APTD, TTD, SL Summary reports Calculations and ratios • FL/BPD IOTA (International Ovarian Tumor Analysis) LR2 • FL/AC 4 worksheet • FL/HC • HC/AC Vascular Measurements/Calculations • CI (Cephalic Index) SYS DCCA (Systolic Distal Common Carotid Artery) • AFI (Amniotic Fluid DIAS DCCA (Diastolic Distal Common Carotid Index) Artery) • CTAR (Cardio -Thoracic Area Ratio) SYS MCCA (Systolic Mid Common Carotid Artery) • MCA PS(Middle DIAS MCCA (Diastolic Mid Common Carotid Artery) Cerebral Artery Peak SYS PCCA (Systolic Proximal Common Carotid
[Page 11] Artery) Biopsy guide Single-angle, disposable DIAS PCCA (Diastolic Proximal Common Carotid with a disposable Artery) bracket (E8385MJ, SYS DICA (Systolic Distal Internal Carotid Artery) E8333JB), single-angle, DIAS DICA (Systolic Distal Internal Carotid Artery) reusable bracket SYS MICA (Systolic Mid Internal Carotid Artery) (H40412LN) DIAS MICA (Diastolic Mid Internal Carotid Artery) SYS PICA (Systolic Proximal Internal Carotid Artery) E8CS-RS DIAS PICA (Diastolic Proximal Internal Carotid Endocavitory micro convex probe Artery) Applications OB/GYN (Transvaginal), SYS DECA (Systolic Distal External Carotid Artery) Urology (Transrectal) DIAS DECA (Diastolic Distal External Carotid Biopsy guide Single-angle, disposable Artery) with a disposable SYS PECA (Systolic Proximal External Carotid bracket (E8385MJ, Artery) E8333JB), single-angle, DIAS PECA (Diastolic Proximal External Carotid reusable bracket Artery) (H40412LN) VERT (Systolic Vertebral Velocity) SUBCLAV (Systolic Subclavian Velocity) Automatic IMT IC9-RS Endocavitory micro convex probe Summary Report Applications OB/GYN, Urology Urological Calculations (Transvaginal, Bladder volume Transrectal) Prostate volume Biopsy guide Single-angle, disposable Left/right renal volume with a disposable Generic volume bracket (H48691YW), Post-void bladder volume single-angle, reusable bracket (H48701MN) Probes LOGIQ P8 BE9CS-RS C1-5-RS, 8C-RS, E8C-RS, E8CS-RS, IC9-RS, BE9CS- Endocavitory micro convex probe RS, ML6-15-RS, L3-12-RS, L4-12t-RS, 12L-RS, L6- Applications Urology (Transrectal) 12-RS, 9L-RS, L8-18i-RS, 3Sc-RS, 6S-RS, 12S-RS, Biopsy guide Single-angle, disposable RAB2-6-RS, RIC5-9A-RS, P8D, P6D, P2D, 6Tc-RS, with a disposable C2-7-D and 10C-D probes bracket (E8387M, H42742LH, H42742LJ), C1-5-RS single-angle, reusable Convex probe bracket (E8387MA) Applications Abdomen (incl. Pleural), ML6-15-RS transcranial), OB/GYN, Matrix array linear probe Urology Applications Small Parts, Vascular Biopsy guide Multi-angle, disposable with a reusable bracket transcranial), Pediatric, (H40432LE) Neonatal, Musculoskeletal 8C-RS Biopsy guide Multi-angle, disposable Micro convex probe with a reusable bracket Applications Pediatrics, Neonatal (H40432LJ) L3-12-RS Linear probe E8C-RS Applications Endocavitory micro convex probe Abdomen (incl. Pleural), Applications OB/GYN (Transvaginal), transcranial), Small Parts, Urology (Transrectal)
[Page 12] Pediatric, Neonatal, Musculoskeletal, Breast Peripheral Vascular Biopsy guide Multi-Angle, disposable Biopsy guide N/A with a reusable bracket (H48302AA) 3Sc-RS Phased array sector probe L4-12t-RS Applications Cardiac, Abdomen (incl. Linear probe Pleural), Transcranial Applications Abdomen (incl. Pleural), Biopsy guide Multi-angle, disposable Small Parts, Vascular (No with a reusable bracket transcranial), Pediatric, (H46222LC) Neonatal, Musculoskeletal, Breast 6S-RS Biopsy guide Multi-angle, disposable Phased array sector probe with a reusable bracket Applications Cardiac, Pediatrics, (H40432LC) Neonatal single-angle, disposable with a reusable bracket (H48392LT: free hand, H48392LL: 12S-RS transverse) Phased array sector probe Applications Pediatrics, Neonatal 12L-RS Biopsy guide N/A Linear probe Applications Small Parts, Vascular (No transcranial), Pediatric, RAB2-6-RS Neonatal, Convex volume probe Musculoskeletal Applications Abdomen, OB/GYN, Biopsy guide Multi-angle, disposable Urology with a reusable bracket Biopsy guide Multi-angle, disposable (H40432LC) with reusable bracket (H48681ML) L6-12-RS Linear probe RIC5-9A-RS Applications Abdomen (incl. Pleural), Endocavitory micro convex volume probe Applications OB/GYN (Transvaginal), transcranial), Small Parts, Urology (Transrectal) Pediatric, Neonatal Biopsy guide Single-angle, disposable Biopsy guide Multi-angle, disposable with a disposable with a reusable bracket bracket (H48681GF), (H40432LC) single-angle, reusable bracket (H46721R) 9L-RS Linear probe P8D Applications Abdomen (incl. Pleural), CW split crystal probe Small Parts, Vascular (No Applications Cardiac, Vascular (No transcranial), Pediatric transcranial) Biopsy guide Multi-angle, disposable with a reusable bracket (H4906BK) P6D CW split crystal probe L8-18i-RS Applications Cardiac, Vascular (No Linear probe transcranial) Applications Small Parts, Vascular (No transcranial), Neonatal, Pediatrics, P2D Intraoperative , CW split crystal probe
[Page 13] Applications Cardiac, Vascular (No • IEC/EN 60601 -2-37 Medical electrical equipment transcranial) – Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment 6Tc-RS • IEC 61157 (Standard means for the reporting of TEE Sector (Trans-esophageal) Probe the acoustic output of medical diagnostic Applications Cardiac ultrasonic equipment) (Transesophageal) • IEC/EN 62366 Application of usability engineering to medical devices • IEC/EN 62304 Software Life Cycle Processes C2-7-D • IEC/EN 62359 Ultrasonic - Field characterization - Convex probe Test methods for the determination of thermal and Applications Abdomen (incl. Pleural) mechanical indices related to medical diagnostic ultrasonic fields Biopsy guide Multi Angle, disposable with a reusable bracket • EN ISO 15223 -1: Symbols to be used with medical (H40482LK), Multi Angle, device labels, labelling and information to be reusable bracket supplied (H404822LL) • ISO 10993 -1 Biological evaluation of medical devices – Part 1 Evaluation and testing • ISO14971:2012(Medical devices - Application of 10C-D risk management to medical devices) Micro Convex probe • EMC Emissions Group 1, class A, Class B device Applications Pediatric, Neonatal, requirements as per Sub clause 4.2 of CISPR 11 • WEEE (Waste Electrical and Electronic transcranial) Equipment) Biopsy guide N/A • ROHS according to 2011/65/EU Including national deviations Inputs and Outputs • Wireless equipment shall be certified to FCC, RED HDMI out and Japan Radio Law Ethernet network (RJ45) •Medical Device Good Manufacturing Practice S-video out Manual issued by the FDA (Food and Drug Composite video out Administration, Department of Health, USA). USB (2x in front (USB 3.0), 3x in rear) AC power input Safety Conformance The LOGIQ P8 is: Conforms to the following standards for safety: Classified to ANSI/AAMI ES60601-1 2005 R1 2012 Medical Electrical Equipment, Part 1: General Requirements for Safety by a Nationally Recognized Test Lab Certified to CSA CAN/CSA-C22.2 NO. 60601-1 :14 General requirements for safety CE Marked to Council Directive 93/42/EEC on Medical Devices • IEC/EN 60601 -1 3.1 Edition. Medical electrical equipment – Part 1: General requirements for basic safety and essential performance • IEC/EN 60601 -1-2 Medial electrical equipment – Part 1-2: General requirements for safety Collateral Standard: Electromagnetic compatibility – requirements and tests • IEC/EN 60601 -1-6 Medical electrical equipment Part 1 -6: General requirements for basic safety and essential performance – Collateral Standard: Usability
[Page 14] 1. The LOGIQ P8 is a highly mobile and easy to use, performance multi-purpose color doppler imaging system, designed for Abdominal, Small Parts, Musculoskeletal, Breast, Vascular, Cardiology, Transcranial, Urology, Pediatric, Neonatal, Obstetrics Transesophageal and Gynecology applications. 2. Contrast Enhanced Ultrasound is available in the U.S. for characterization of focal liver lesions and left ventricle opacity only. 3. Elastography with semi-Quantification (Elastography Quantification) described in this material has not been cleared by the U.S. FDA and is not available for promotion or sale in the United States. 4. Available on region regulatory clearance Imagination at work Product may not be available in all countries and regions. Full product technical specification is available upon request. Contact a GE Healthcare Representative for mor e information. Please visit www.gehealthcare.com/promotional-locations Data subject to change. © 2021 General Electric Company. GE, the GE Monogram, imagination at work, LOGIQ, B-Flow, InSite and CrossXBeam are trademarks of General Electric Company. DICOM is the registered trademark of the National Electrical Manufacturers Association. Reproduction in any form is forbidden without prior written permission from GE. Nothing in this material should be used to diagnose or treat any disease or condition. Readers must consult a healthcare professional. February 2021 DOC2463984